Model: HHLD

Product introduction: HHLD electromagnetic flowmeter is an induction meter that measures the volume flow of conductive medium in the tube according to Faraday's law of electromagnetic induction. It adopts single-chip embedded technology to realize digital excitation. At the same time, CAN field bus is used on the electromagnetic flowmeter. HHD electromagnetic flowmeter can output 4-20mA current signal for recording, adjustment and control while meeting on-site display. It has been used in chemical industry, environmental protection, metallurgy, medicine, papermaking, water supply and drainage and other industrial technologies and management doors.

Detailed introduction:

Split electromagnetic flowmeter has the following characteristics:

HHLD split electromagnetic flowmeter can output standard current signal (4-20mA) while meeting on-site monitoring and display for recording, adjustment and control; it can be used in chemical industry, environmental protection, textile, metallurgy, mining, medicine, papermaking, Liquid flow measurement of conductive medium in water supply, food, sugar, brewing and other industries; in addition to measuring general conductive liquids, according to the special needs of users, it can also measure conductive liquid-solid two-phase flow, high-viscosity liquids and salts, The flow of liquids such as strong acids and alkalis. It is used in chemical fiber, food, paper, sugar, mining and metallurgy, water supply and drainage,

1. Suitable for liquid flow detection with conductivity greater than 5μs/cm. Changes in conductivity do not affect changes in performance

2. The electromagnetic flowmeter has long-term high measurement accuracy, and is actually not affected by the physical characteristics of the fluid

3. Easy to put into operation, the flowmeter is automatically set according to the range of 0~10m/s, no need to change the measurement range

4. All parts in contact with the measured medium have good corrosion resistance and wear resistance, and have a wide range of applications

5. There are no moving parts in the pipeline, no flow blocking parts, almost no additional pressure loss during measurement

6. The measurement result has nothing to do with the flow rate distribution, fluid pressure, temperature, density, viscosity and other physical parameters

7. The range can be modified online according to the actual needs of the user at the scene

8. High-definition backlit LCD display, full Chinese menu operation, easy to use, simple to operate, easy to learn and understand

9. All-digital processing, strong anti-interference ability, reliable measurement, high precision, flow measurement range up to 150:1

10. There are three internal totalizers that can respectively display the forward cumulative reverse cumulative amount and the difference cumulative amount, and there is a non-power-off clock inside.

Can record power-down time

11. With 4-20mA, RS485, RS232, Hart and Modbus communication signal output

12. With self-inspection and self-determination functions

13. The electromagnetic flowmeter is easy to use. After installation, it only needs to be connected to the power supply without any other operations. The standard signal can be output, which is convenient

Non-professional use. No mechanical moving parts, usually no maintenance

technical parameter

1. Ambient temperature: -10—+50℃

2. Accuracy grade: pipeline type: 0.5 grade, 1.0 grade

3. The temperature of the measured medium:

Ordinary rubber lining: -20—+60℃;

High temperature rubber lining: -20—+90℃

PTFE lining: -30—+100℃;

High temperature type PTFE lining: -30—+180℃

4. Rated working pressure:

DN10—DN65:2.5MPa DN80—DN150:1.6MPa

DN200—DN1200:1.0MPa DN700—DN3000:0.6MPa

5. Output signal and load resistance: 4-20mADC, 0-500Ω

6. Electrode material: stainless steel containing molybdenum, titanium (Ti), tantalum (Ta) Hastelloy (HB), etc.

7. Protection level: diving type: IP68, others: IP65

8. Power supply: 220VAC

9. Length of straight pipe section: pipeline type: upstream≥5DN, downstream≥2DN

10. Connection method:

The electromagnetic flowmeter is installed in pipeline, and flange connection is adopted between it and the piping.

The flange connection size should meet the requirements of GB9119-88.

The integrated electromagnetic flowmeter has the following characteristics:

HHLD integrated electromagnetic flowmeter can output standard current signal (4~20mA) while meeting on-site monitoring and display for recording, adjustment and control; it can be used in chemical industry, environmental protection, textile, metallurgy, mining, medicine, papermaking, Liquid flow measurement of conductive medium in water supply, food, sugar, brewing and other industries; in addition to measuring general conductive liquids, according to the special needs of users, it can also measure conductive liquid-solid two-phase flow, high-viscosity liquids and salts, The flow of liquids such as strong acids and alkalis. It is used in chemical fiber, food, paper, sugar, mining and metallurgy, water supply and drainage,

1. Suitable for liquid flow detection with conductivity greater than 5μs/cm. Changes in conductivity do not affect changes in performance

2. The electromagnetic flowmeter has long-term high measurement accuracy, and is actually not affected by the physical characteristics of the fluid

3. Easy to put into operation, the flowmeter is automatically set according to the range of 0~10m/s, no need to change the measurement range

4. The parts in contact with the measured medium have good corrosion resistance and wear resistance, and have a wide range of applications

5. There are no moving parts in the pipeline, no flow blocking parts, almost no additional pressure loss during measurement

6. The measurement result has nothing to do with the flow rate distribution, fluid pressure, temperature, density, viscosity and other physical parameters

7. The range can be modified online according to the actual needs of the user at the scene

8. High-definition backlit LCD display, full Chinese menu operation, easy to use, simple to operate, easy to learn and understand

9. All-digital processing, strong anti-interference ability, reliable measurement, high precision, flow measurement range up to 150:1

10. There are three internal totalizers that can respectively display the forward cumulative reverse cumulative amount and the difference cumulative amount, and there is a non-power-off clock inside.

Can record power-down time

11. With 4-20mA, RS485, RS232, Hart and Modbus communication signal output

12. With self-inspection and self-determination functions

13. The electromagnetic flowmeter is easy to use. After installation, it only needs to be connected to the power supply without any other operations. The standard signal can be output, which is convenient

Non-professional use. No mechanical moving parts, usually no maintenance

technical parameter

1. Ambient temperature: -10—+50℃

2. Accuracy grade: pipeline type: 0.5 grade, 1.0 grade

3. The temperature of the measured medium:

Ordinary rubber lining: -20—+60℃;

High temperature rubber lining: -20—+90℃

PTFE lining: -30—+100℃;

High temperature type PTFE lining: -30—+180℃

4. Rated working pressure:

DN10—DN65:2.5MPa DN80—DN150:1.6MPa

DN200—DN1200:1.0MPa DN700—DN3000:0.6MPa

5. Output signal and load resistance: 4-20mADC, 0-500Ω

6. Electrode material: stainless steel containing molybdenum, titanium (Ti), tantalum (Ta) Hastelloy (HB), etc.

7. Protection level: diving type: IP68, others: IP65

8. Power supply: 220VAC, 24VDC, 3.6V lithium battery

9. Length of straight pipe section: pipeline type: upstream≥5DN, downstream≥2DN

10. Connection method:

The electromagnetic flowmeter is installed in pipeline, and flange connection is adopted between it and the piping.

The flange connection size should meet the requirements of GB9119-88.

Keyword:
Split type anticorrosive electromagnetic flowmeter
We could not find any corresponding parameters, please add them to the properties table

Related Products

1
 Integrated electromagnetic flowmeter
Integrated electromagnetic flowmeter
Product introduction: HHLD electromagnetic flowmeter is an induction meter that measures the volume flow of conductive medium in the tube according to Faraday's law of electromagnetic induction.
 Plug-in electromagnetic flowmeter
Plug-in electromagnetic flowmeter
The measurement principle of the plug-in electromagnetic flowmeter is Faraday's law of electromagnetic induction.
 Battery-powered electromagnetic flowmeter
Battery-powered electromagnetic flowmeter
The battery-powered electromagnetic flowmeter uses a 16-bit embedded ultra-micro power consumption microprocessor and a sensor excitation system designed with special technology.
 Clamp-connected electromagnetic flowmeter
Clamp-connected electromagnetic flowmeter
Product introduction: HHLD electromagnetic flowmeter is an induction meter that measures the volume flow of conductive medium in the tube according to Faraday's law of electromagnetic induction.

Online Inquiry

Product information

Product serial number
Thumbnail
Name of product
Retail price
Expected unit price
*Order quantity
Operation
Product serial number:
$formItem.imageUrl
Split type anticorrosive electromagnetic flowmeter
Retail price: 0.0
* Expected unit price
*Order quantity
-+
Remove

Contact information

Basic information
Method of contact and profession
Company information
Verification Code

Add product X

Product categories:
All products
Selected 0 Each
搜索

Navigation

Copyright © 2021 Kaifeng Henghe Flow Meter Co., Ltd.        豫ICP备2021035603号-1        Powered by www.300.cn        This website already supports IPv6

Copyright  © 2021 Kaifeng Henghe Flow Meter Co., Ltd.
豫ICP备2021035603号-1
Powered by www.300.cn
This website already supports IPv6